Product · Engineering

DraftGuard

AI review for engineering drawings & technical documentation

DraftGuard reads your drawing packages (PDF, DXF/DWG, scans) and their documents, finds missing or inconsistent information, compares revisions and drafts documentation from your templates — and shows every finding on the sheet, with the evidence and a proposed fix.

110 mechanical + 93 electrical checks, every finding on the sheet

Solutions
Built for

The challenge

The problem DraftGuard solves

Drawing checking is done by hand, sheet by sheet, under deadline — and the errors it misses are found at the supplier, in inspection or on site, where they cost the most.

01

Slow: a checker reads every dimension, note and title block field by hand

02

Inconsistent: what gets checked depends on who checks and how busy they are

03

Late: errors found at the supplier or on site cost far more than at the drawing board

04

Drifting documents: specifications, inspection plans and schedules no longer match the revision

Overview

What DraftGuard does

A first, complete check of every drawing and document in the project, before a human signs it off. Most checks are deterministic engineering rules; the AI only steps in where judgement is needed.

01

Review every sheet against ISO / ASME and NF C 15-100 practice

02

Compare revisions and catch changes missing from the revision table

03

Cross-check drawings against specifications, inspection plans and parts lists

04

Generate documents (DOCX + PDF) from the drawing and your templates

05

Build cable schedules, CCTP coverage, DOE and take-off for electrical projects

06

Ask the project agent — answers cite the sheet, actions wait for your confirmation

Two domains, one review agent

Built for mechanical and electrical design offices

Each domain has its own reading, rule catalog and deliverables, on the same platform.

110 rules · 98 deterministic, 12 AI-assisted

Mechanical

Part and assembly drawings read into a structured model: title block, revisions, notes, dimensions, GD&T, threads, surface finish, parts list and balloons, views.

  • Title block, dimensioning, tolerancing and GD&T checks (ISO 7200, ISO 1101, ISO 5459, ISO 2768, ASME Y14.5)

  • Balloons ↔ parts list consistency on assemblies

  • Revision comparison: side by side, overlay, swipe, with a change summary

  • Inspection plan, part specification, change notice and traveller generated from the drawing

93 EL rules · 88 deterministic, 5 AI-assisted

Electrical

Single-line diagrams, power and control schematics and layout plans read into folios, components, circuits, cables, cross-references, terminals and rooms.

  • Protection, cable, cross-reference and layout checks (NF C 15-100, EN 61082, EN 60204-1)

  • Cable schedule built from the plans and compared with yours (XLSX / DOCX)

  • CCTP coverage matrix, DOE index and assembly, quantity take-off

  • Site markups turned into a change list, redline and revision row, then verified in the next revision

Inside the product

From the uploaded sheet to the signed-off package

Real screens from DraftGuard, on a demo pump assembly and an electrical workshop extension.

01

Every value read, every value located

Each sheet becomes a structured model: title block fields, dimensions, tolerances, GD&T frames, surface finish, notes and revisions, each outlined on the drawing with its confidence.

  • Title block, dimensions, GD&T and notes in the Model tab

  • Corrections by hand, JSON and CSV export

  • Vector PDF, DXF and scans with OCR

Every value read, every value located
02

Findings with the evidence and the fix

A datum referenced but never defined, a missing general tolerance note: each finding comes with its rule, its standard, a crop of the sheet, a recommendation and its status history.

  • Severity and a release score per drawing

  • Accept, mark false positive or set a status

  • Rules switched off or re-graded per project

Findings with the evidence and the fix
03

Revisions compared, unrecorded changes flagged

Two revisions side by side, overlaid or swiped. The change summary lists every dimensional, note and title block change — and the ones missing from the revision table become findings.

  • Side by side, overlay and swipe views

  • Change summary by category

  • Comparison report in PDF

Revisions compared, unrecorded changes flagged
04

The drawing and its documents, cross-checked

The inspection plan, specification and parts list are read and compared with the drawing: a characteristic the drawing does not give, a dimension the plan forgets.

  • Drawing ↔ inspection plan, specification, parts list

  • Linked document and line on every finding

  • Proposed alignment value

The drawing and its documents, cross-checked
05

Documents drafted from the drawing

An inspection plan generated from the drawing model and your Word template, then checked like any upload — missing values are flagged, never invented.

  • Inspection plan, part specification, change notice, traveller

  • DOCX and PDF output

  • Template edit by instruction

Documents drafted from the drawing
06

Electrical folios checked, finding by finding

On single-line diagrams and schematics, a breaker rated above its conductor or a socket circuit without 30 mA protection is flagged on the folio, with the evidence.

  • Protection, cables, cross-references, layout

  • NF C 15-100 / EN 61082 / EN 60204-1 based tables

  • Sizing findings always call for a calculation note

Electrical folios checked, finding by finding
07

The cable schedule, built from the plans

Every cable read from the plans, with where each value comes from — and every difference with the schedule you uploaded.

  • Provenance for each value

  • Differences with the uploaded schedule

  • XLSX and DOCX export

The cable schedule, built from the plans
08

CCTP coverage, requirement by requirement

Each requirement of the specification is matched against the plans and documents: covered, partial, not verified or contradicted, with its evidence.

  • Coverage status and evidence per article

  • Contradictions raised as findings

  • XLSX export

CCTP coverage, requirement by requirement

How it works

How DraftGuard works

  1. Step 1

    Upload

    Drop the drawing package and its documents: PDF (vector or scanned), DXF, DWG, images, DOCX, XLSX.

  2. Step 2

    Read

    Each sheet is read into a structured model — title block, dimensions, tolerances, notes, parts list, circuits — and every value keeps its place on the sheet.

  3. Step 3

    Check

    Deterministic rules run first; AI-assisted rules handle the cases that need judgement, gated by confidence.

  4. Step 4

    Review & deliver

    The engineer accepts or dismisses each finding on the sheet, then exports the check report, comparison report and generated documents.

Outcomes

Outcomes teams see

94.7%

of seeded drawing defects detected

100%

of seeded revision changes found

97.4%

of drawing ↔ document mismatches detected

100%

of electrical cable schedule rows rebuilt from the plans

Measured on our benchmark of synthetic drawing sets with known, seeded defects (40 mechanical projects, 30 electrical projects). Per-rule precision and recall are published in the product.

Use cases

Where DraftGuard fits

Pre-release drawing check

Every drawing gets a complete first check before it goes to the checker, the supplier or the workshop.

Revision control

See every change between two revisions, and the ones nobody wrote in the revision table.

Inspection & quality documents

Inspection plans and specifications generated from the drawing, and kept consistent with it.

Electrical tender & handover

Cable schedule, CCTP coverage, take-off and DOE prepared from the plans instead of by hand.

Site feedback

Marked-up plans from site become a reviewed change list, a redline and a revision row.

Supplier drawing intake

Check incoming drawings and scans against your standards before you accept them.

Under the hood
  • ISO 7200
  • ISO 1101
  • ISO 2768
  • ASME Y14.5
  • NF C 15-100
  • EN 61082
  • EN 60204-1
  • PDF · DXF · DWG · scans
  • DOCX · XLSX
  • On-premise (Docker)
  • Claude AI

FAQ

Frequently asked questions about DraftGuard

See DraftGuard on your own drawings.

Book a 30-minute live demo: we run DraftGuard on a drawing package of yours and walk you through every finding.